Structures Unlimited, Inc.


A SUMMARY OF SPECIFICATIONS

Panel Width: 4' and 5' (1220mm and 1500mm) standard. Other widths up to 5' 0" (1500mm) are optional.

Panel Length: 3' to 20' (914mm to 6096mm) standard, 16' max. (5000mm) for skyroofs.

Panel Thickness: 4" (100mm), 2-3/4" (70mm), 1-9/16" (40mm). 1" (30mm) and 5/8" (16mm) thick glazing panels available.

Weight: Most panels and systems weigh under 3 PSF (14.65 kg/m2).

Color: Crystal, White, Optional Kal-tint Panels, translucent insulation can be virtually any color to create dazzling results.

Surface Texture: flat, or pebble as option.

Grid Pattern: 12" x 24" (300mm x 600mm), reverse, 8" x 20" (200mm x 500mm), 10" x 10" (250mm x 250mm), 12" x 12" (300mm x 300mm) Tuckerman.

Materials: Translucent FRP faces. Other options include opaque faces, windows and louvers, aluminum grid, composite grid, fiberglass or aerogel insulation, aluminum and thermally broken installation systems.

U-Value Range: .53 to .05 (U-value SI conversion: 1.0 w/m2k=0.176 BTU/(hr / ft2 / °F)) for panels; NFRC system certification range .43 to .10.

Light Transmission: 0 to 65%.

Impact: Standard exterior faces will withstand 70 ft.-lbs. impact. Optional hi-impact faces will withstand 230 ft.-lbs. (311J) impact, Hurricane-Resistant and Blast-Resistant Systems also available.

Chemical Resistance: Most anything allowed by EPA and OSHA.

Weathering: Kalwall's exterior face is made with innovative super-weathering and colorfast resins the full thickness... not a low-grade substrate overlaid with thin plastic film or gel to simulate weatherability. All standard exterior faces include a permanent glass veil erosion barrier to prevent "fiber bloom"! This is just one built-in quality bonus not offered by look-alikes!

Sound: Average transmitted by test, excellent performance.

Fire: Although some Kalwall panels contain combustible binder resins (ignition temperature greater than 800ºF), they will withstand a 1200ºF flame for one hour with no flame penetration. Kalwall panels pass the Class "A" Burning Brand Test (ASTM E-108). A special configuration of Kalwall is a UL Listed Class A Roof system. All interior faces are 1 in. or less Burn Extent, by ASTM D-635. Several categories of interior flame-spread/smoke developed by UL 723 tunnel tests, including Class 1, are available. Kalwall is listed by: ICC #PFC-1705; ICC #9446; several state and local areas and U.L. Canada. British Standard 476, Parts 3, 6, 7. FM Class I and NFPA 268 – Radiant Panel Test-Exterior Walls. Whenever reference is made to fire tests, the numerical rating is not intended to reflect hazards presented by this or any other material under actual fire conditions.

Bond Strength: Panels are a specially engineered composite designed for maximum architectural and structural life. Panels and adhesives are tested according to the stringent requirements of "Criteria for Sandwich Panels" issued by ICC (International Code Council) and must pass severe tensile and shear tests before and after numerous exposure conditions. Before specifying an alternate, insist on actual field proof of bond integrity over a 25-year period. Caution is urged in accepting "look-alikes" as equivalents.

Expansion: The coefficient of linear thermal expansion of Kalwall is 1.24 x 10-5 in/in/ºF. (2.23 x 10-5 mm/mm/ºC). An 8' panel will expand lengthwise approximately 1/8" when the temperature rises 100ºF or a 2 m long panel will expand approximately 2 mm when the temperature rises 40ºC.

NFRC Certified U-Factors as of 2004:

For identification purposes, we refer to the panel U-factors based on the 1994 NFRC test. Certified U-factors are based on a model of the system, 80" x 80" and consist of 2 panels, a center batten as well as head, sill and jamb members. All site-built sloped glazing and skylight systems are modeled at this size, allowing direct product comparisions.

ROOFS

.

Panel Only

(1994)

2" Batten

Stiffener*

3-1/4" IS**

U-Factor

Product #

U-Factor

Product #

U-Factor

Product #

Thermally Broken

0.23

0.28

001-009

0.30

001-001

0.33

001-005

0.14

0.20

001-011

0.22

001-003

0.25

001-007

0.10

0.17

001-012

0.18

001-004

0.21

001-008

0.05

0.11

001-029

n/a

.

n/a

.

Non-Thermally Broken

0.29

0.42

004-009

0.43

004-001

0.46

004-005

0.22

0.35

004-011

0.36

004-003

0.39

004-007

0.18

0.31

004-012

0.33

004-004

0.35

004-008

* Stiffener group includes: #2SSSE, #4SSSE, #12SSSE and Structural Tee Battens (walls only).
** 3-1/4" IS group includes the 4-1/2" fin batten (walls only).

Things to remember:

U-factors are for comparison of like products, not energy calculations as actual installed U-factor may vary from the certified vale due to size difference.

Thermally broken systems use thermally broken perimeter. Non-thermally broken systems use standard aluminum perimeter. A thermally broken panel in non-thermally broken perimeter is not an NFRC certified product.

Certified products may be found listed in the NFRC Certified Products Directory or online at www.nfrc.org.

NEW! Tested assemblies by AAMA 1503.1-88 for air and water infiltration, structural integrity and overall thermal properties. Overall U-factor = .14 available!

Special Approvals and Listings:
• FM Roof Systems standards 4881 and 4471
• S. Florida Hurricane-Resistant Systems
• NFRC Certified Products Listing
• UL Listings for Class A Roof System and Faces
• DoD/GSA Blast Resistant Construction per DoD UFC 4-010-01 optional

Computer-Modeled Daylight Analysis: Take the guesswork out of natural daylight level estimating and qualify your needs – contact us!

Technology and manufacturing from a single source. Translucent faces continuously manufactured for unparalleled longevity and fire performance enhance comfort while adding performance and structural integrity beyond comparison.


Home  |  Who We Are  |  Specification Summaries  |  CAD Drawings